Magnetic Type IEC61009-1 10ka 1p+N 30/100/300mA RCCB with Overcurrent Protection RCBO Circuit Breaker with Ce CB TUV

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: Conventional Circuit Breaker
Samples:
US$ 5.7/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Other

Basic Info.

Model NO.
KNLN6-63
Poles Number
2
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, RCCB, Overcurrent Protection~@~Circuit-Breaker Failure P
Certification
ISO9001-2000, CE, CB
Frame Class
32A
Rated Working Voltage
240V
Rated Frequency
50/60Hz
Rated Working Current
6,10,16,20,25,32A
Transport Package
Carton
Specification
CE; ROHS; CCC
Trademark
korlen
Origin
Wenzhou; Zhejiang; China
HS Code
8536200000
Production Capacity
500000PCS/Year

Product Description

KNBL1-32 series leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut off the power within 0.1s to protect human safety and prevent the accident due to the current leakage.
KNBL1-32 series leakage breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and short-circuited as wellas infrequent changeover of the line in normal situation. It complies with standard of IEC/EN61009-1 and GB16917.1.
Frame class 63A
Rated working voltage 240V
Rated frequency 50/60Hz
Rated working current 16,20,25,32,40,50,63A
Rated limiting short-circuit current 10000A
Release type B,C
Pole number 1P+N
Mechanical life 4000
Electric life 20000
Sequence NO. Release Test
current I/In
Start state Tripping
time
Expected
restlt
1 C 1.13In Cold state t≤1h Not tripping
2 C 1.45In Start right after
the serial NO .
1 test
t<1h tripping
3 C 2.55In Cold state 1s<t<60s tripping
4 C 5In Cold state t≤0.1s Not tripping
5 C 10In Cold state t<0.1s tripping
Magnetic Type IEC61009-1 10ka 1p+N 30/100/300mA RCCB with Overcurrent Protection RCBO Circuit Breaker with Ce CB TUV
Magnetic Type IEC61009-1 10ka 1p+N 30/100/300mA RCCB with Overcurrent Protection RCBO Circuit Breaker with Ce CB TUV
Magnetic Type IEC61009-1 10ka 1p+N 30/100/300mA RCCB with Overcurrent Protection RCBO Circuit Breaker with Ce CB TUV

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Other
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001