Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 0.72/Piece
Request Sample
Manufacturer/Factory, Other

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001
  • Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p
  • Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p
  • Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p
Find Similar Products

Basic Info.

Model NO.
KNB2-63
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
DIN Rail
Structure
MCB
Poles Number
1,2,3,4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC
Patented
Patented Product
ISO
ISO9001
Release Type
B C D
Rated Working Voltage
240/415V
Rated Frequency
50/60Hz
Rated Working Current
6,10,16,20,25,32,40,50,63A
Making and Breaking Capacity
10ka
Pole
1,2,3,4
Mechanical Life
10000
Electric Life
4000
Transport Package
Carton
Specification
1P 7.78x7.85x17.8mm
Trademark
KORLEN
Origin
China
HS Code
8536200000
Production Capacity
2000000/Month

Product Description

Product Description

        KNB2-63 series Miniature Circuit Breaker is nice in appearance, reasonable in structure, sound in feature and high in breaking capacity. Installed with standard din rail, it is convenient and easy in usage. It is mainly used in the line of AC 50/60Hz, rated working voltage to 240V/415V, and rated current to 63A as protection against overload and short-circuit. It can be used as infrequent on-and-off operation and changeover.
        It complies with standard of GB10963 and IEC/EN60898.

 
  Standard
 
  IEC/EN 60898-1
 
IEC/EN 60947-2
 
Electrical features Rated current In
 
A         1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50,63
 
Poles
 
  1P, 1P+N, 2P, 3P, 3P+N, 4P
 
1P, 2P, 3P, 4P
 
Rated voltage Ue
 
V                                 230/400~240/415
Insulation voltage Ui
 
V 500
Rated frequency
 
  50/60Hz
Rated breaking capacity
 
A 10000 10000
Energy limiting class
 
  3  
Rated impulse withstand voltage(1.2/50) Uimp
 
V 4000
Dielectric test voltage at ind. Freq. for 1 min
 
KV 2 1.890
Pollution degree
 
  2
Power loss per pole   Rated current (A) 
 
Max power loss per pole (W)
 
  1, 2, 3, 4, 6, 10
 
2
  16, 20, 25, 32
 
3.5
  40, 50, 63
 
5
Thermo-magnetic release characteristic
 
  B, C, D
 
(8-12)In
 
Mechanical features Electrical life
 
  4000
Mechanical lif
 
  20000
Contact position indicator
 
  YES
Protection degree
 
  IP20
Reference temperature for setting of thermal element

 
ºC
 
30
Ambient temperature (with
daily average≤35ºC)
 
ºC
 
-5...+40
Storage temperation
 
ºC
 
-25...+70
Installation Terminal connection type
 
  Cable/U-type busbar/Pin-type busbar
Terminal size top/bottom for  cable mm2
 
25
AWG
 
18-4
Terminal size top/bottom for  busbar mm2
 
10
AWG 18-8
Tightening torque N·m 2.5
In-Ibs. 22
Mounting   On DIN rail EN 60715 (35mm) by means of fast clip device
Connection   From top and bottom
Combination with accessories Auxiliary contact   YES
Shunt release   YES
Under voltage release   YES
Alarm contant   YES
 
    1. Selectivity
 







Load side: K    NB1-63, KNB1-63H
Curve B, C
In (A) Power supply side: RT36-00 (fuse)
20 25 36 50 63 80 100 125 160
Is (kA)
≤2 1.2 4 >12 >12 >12 >12 >12 >12 >12
3 0.7 1.2 3.8 5.3 6 6 6 6 6
4 0.6 0.9 2.5 3.8 6 6 6 6 6
6 0.5 0.8 1.9 2.5 4.5 5 6 6 6
10   0.7 1.4 2.2 3.2 3.6 6 6 6
16     1.2 1.8 2.6 3 5.6 6 6
20       1.5 2.2 2.5 4.6 6 6
25       1.3 2 2.2 4.1 5.5 6
32         1.7 1.9 3.8 4.5 6
40           1.7 3 4 5
50           1.5 2.6 3.5 4.5
63             2.4 3.3 4.5
 




Load side: KNB1-63, KNB1-63H
Curve B, C
In (A) Power supply side: NM8-100S/H/R
16 20 25 32 40 50 63 80 100
Is (kA)
≤10 0.19 0.19 0.3 0.4 0.5 0.5 0.5 0.63 0.8
16     0.3 0.4 0.5 0.5 0.5 0.63 0.8
20         0.5 0.5 0.5 0.63 0.8
25           0.5 0.5 0.63 0.8
32             0.5 0.63 0.8
40               0.63 0.8
50                 0.8
63                  
    1. Backup protection
 






Load side:K NB1-63, KNB1-63H
Curve B, C
In (A) Power supply side: RT16 series
40 50 63 80 100 125 160
Is (kA)
1~6 40 40 40 40 40 40 40
8~10 40 40 40 40 40 40 40
13 40 40 40 40 35 35 35
16 40 40 40 40 30 30 30
20 40 40 40 40 30 30 30
25 40 40 40 40 30 30 30
32 40 40 40 40 30 30 30
40 40 40 40 40 30 30 30
50 30 30 30 30 30 30 30
63 20 20 20 20 15 15 15
 


Load side: KNB1-63, KNB1-63H
Curve B, C
In (A) Power supply side: NM8
NM8-125S NM8-125H NM8-125R NM8-250S NM8-250H NM8-250R
Is (kA)
1~6 15 18 18 15 15 15
10~20 12 15 15 12 12 12
32~40 12 15 15 12 12 12
50~60 12 15 15 12 12 12


 
    1. Temperature derating
The maximum permissible current in a circuit breaker depends on the ambient temperature where the circuit breaker is
placed. Ambient temperature is the temperature inside the enclosure or switchboard in which the circuit breakers are installed.

The reference temperature is 30ºC

 
Ambient temperature                        
  -35ºC -30ºC -20ºC -10ºC 0ºC 10ºC 20ºC 30ºC 40ºC 50ºC 60ºC 70ºC
Rated current(A)                        
1 1.30 1.26 1.23 1.19 1.15 1.11 1.05 1.00 0.96 0.93 0.88 0.83
2 2.60 2.52 2.46 2.38 2.28 2.20 2.08 2.00 1.92 1.86 1.76 1.66
3 3.90 3.78 3.69 3.57 3.42 3.30 3.12 3.00 2.88 2.79 2.64 2.49
4 5.20 5.04 4.92 4.76 4.56 4.40 4.16 4.00 3.84 3.76 3.52 3.32
6 7.80 7.56 7.38 7.14 6.84 6.60 6.24 6.00 5.76 5.64 5.28 4.98
10 13.20 12.70 12.50 12.00 11.50 11.10 10.60 10.00 9.60 9.30 8.90 8.40
16 21.12 20.48 20.00 19.20 18.40 17.76 16.96 16.00 15.36 14.88 14.24 13.44
20 26.40 25.60 25.00 24.00 23.00 22.20 21.20 20.00 19.20 18.60 17.80 16.8
25 33.00 32.00 31.25 30.00 28.75 27.75 26.50 25.00 24.00 23.25 22.25 21.00
32 42.56 41.28 40.00 38.72 37.12 35.52 33.92 32.00 30.72 29.76 28.16 26.88
40 53.20 51.20 50.00 48.00 46.40 44.80 42.40 40.00 38.40 37.20 35.60 33.6
50 67.00 65.50 63.00 60.50 58.00 56.00 53.00 50.00 48.00 46.50 44.00 41.50
63 83.79 81.90 80.01 76.86 73.71 70.56 66.78 63.00 60.48 58.90 55.44 52.29


When several simultaneously operating circuit breakers are mounted side by side in a small enclosure, the temperature rise inside the enclosure causes a reduction in current rating.
You must then assign the rating (already derated if necessary according to ambient temperatuer) a downrating factor of 0.8.



Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p
Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p
Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p
Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p



Shipping:
1. Normally by SEA From NINGBO/SHANGHAI TO .Worldwide..
2. Products are shipped via UPS / DHL / FedEx / TNT and so on expresses (door to door) If the amount is Small.
3. We Provide Drop shipping Service.
4. In order to ensure you receive your order tax free upon import, we can declare lower value according to your demand.

Payment:
1. We usually use T/T (30% deposit before production and 70% to be paid against the copy of B/L).
2. L/C also acceptable

Warranty:
1. We provide 2years warranty.
2. If the product is defective, please notify us within 10 days of delivery.
3. All products must be returned on their original condition, in order to qualify for a refund or exchange of goods
Company Introduction

Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p

Wenzhou Korlen Electric Appliances Co., Ltd, It is a joint venture. My company is a manufacturer including design, development, produce and sale, professional producing MCB, MCCB, RCCB and AC contactor etc. Product enterprises. The company owns import and export power of self-run, expanding Europe and America, Middle East, Southeast Asia etc. Market, set a good Public praise.

The company have more than 1500 workers, including senior engineer among them, engineer at inside of more than 100 technician. And then set up to cover area more than 50 acres, construct area is more than 38000 square meters of the modern industrial zone, providing with the forerunner's standard laboratory and various examination equipments.

Under Korlen people to make great effort unremittingly, designed and developed by oneself, develop and produce the series of MCB, RCCB filled up local blank, attain inter-national advanced level, and acquire more than 20 national patents. The company acquires "30 strong eminent enterprises, top ten of export income, yueqing star class enterprise, attach importance to contract and keeps promise" title of honor for many times past years. Company still the initiative pass ISO 9001 management system verification and 14001 environments management system verification. Our product passed quality verification of domestic and international authority organization like the CB\ SEMKO\ NF\ SIRIM\ SNI\ CE \PCT\ TSE, In the meantime high breaking capacity breaker of our company in this city is the unique product which got " Yueqing famous brand product" by Yueqing people government.

Korlen Electric Appliances is willing to make friends with social public, the world outside businessman join hands together for prosperous society and development to build a brighter future.



Certificates

Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p

Factory Lines

Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p
Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p

Exhibition




Miniature Circuit Breaker 10ka 63A CB Knb2-63 S2 2p


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier