  • Auxiliary Contactor Vacuum Motor AC Contactor LC1-D
  • Auxiliary Contactor Vacuum Motor AC Contactor LC1-D
  • Auxiliary Contactor Vacuum Motor AC Contactor LC1-D
  • Auxiliary Contactor Vacuum Motor AC Contactor LC1-D
  • Auxiliary Contactor Vacuum Motor AC Contactor LC1-D
  • Auxiliary Contactor Vacuum Motor AC Contactor LC1-D
Find Similar Products

Basic Info.

Model NO.
KNC1
Main Circuit Rating Voltage
690V
Main Circuit Rating Current
150A
Type
Ac Contactors
Rated Operation Current
10-400A
Rated Operation Voltage(V)
220V, 230V, 380V, 400V
Ambient Temperature
-5~+40
Action Principle
Electronic Type
Frequency
50/60Hz
IEC
IEC 60947-4
Load
High Power Relay
ISO
ISO9001 ISO14001
Coil Voltage
24, 48, 110, 220, 230, 240, 380, 415, 440V
Transport Package
Carton
Specification
CE
Trademark
korlen
Origin
Wenzhou
HS Code
8537209000
Production Capacity
1000000PCS/Month

Product Description

The series KNC1 AC contactor is applicable at the line of AC 50/60 Hz, rated voltage up to 660V and rated current up to 95A for remote switch, breaking and frequent starting, controlling the AC motor. Moreover, the contactor can act as the time-delay contactor, reve-rsible contactor, star-delta starter by the accessories addition such as addition of modular auxiliary contact set. Air timedelay head, mechanical interlock mechanism, etc. Moreover, it could act as the electromagnetic starter by the direct plug of the thermal relay.

This product conforms to the requirement of IEC60947-4-1& GB14048.4 standards.
Type Rated
insulation
voltage(V)
Conventional
thermal
current(A)
Rated
operation
current(A)
Control power(kw) No .of
contacts
Remark
220V 380V 415V 440V 660V
KNC1-0910
0901
 
660 20 9 2.2 4 4 4 5.5 3P+NO
3P+NC
 
Installation
method
1.with two
screws
2.35mm
din rail
KNC1-1200
1201
 
20 12 3 5.5 5.5 5.5 7.5 3P+NO
3P+NC
 
KNC1-1810
1801
 
32 18 4 7.5 9 9 9 3P+NO
3P+NC
 
KNC1-2510
2501
 
40 25 5.5 11 11 11 15 3P+NO
3P+NC
 
KNC1-3210
3201
 
50 32 7.5 15 15 15 18.5 3P+NO
3P+NC
 
KNC1-4011 60 40 11 18.5 22 22 30 3P+NO+NC Installation
method
1.with three
screws
2.75mm or
35mm
din rail
KNC1-5011 80 50 15 22 25 30 33
KNC1-6511 80 65 18.5 30 37 37 37
KNC1-8011 125 80 22 37 45 45 45
KNC1-9511 125 95 25 45 45 45 45
Type KNC1-09 KNC1-12 KNC1-18 KNC1-25 KNC1-32 KNC1-40 KNC1-50 KNC1-65 KNC1-80 KNC1-95
Pick-up voltage
50/60Hz(V)
(0.85~
1.1)Us
(0.85~
1.1) Us
(0.85~
1.1)Us
(0.85~
1.1)Us
(0.85~
1.1)Us
(0.85~
1.1)Us
(0.85~
1.1)Us
(0.85
~1.1)Us
(0.85~
1.1)Us
(0.85~
1.1)Us
Release voltage
50/60Hz(v)
(0.2~
0.75)Us
(0.2~
0.75)Us
(0.2~
0.75)Us
(0.2~
0.75)Us
(0.2~
0.75)Us
(0.2~
0.75)Us
(0.2~
0.75)Us
(0.2~
0.75)Us
(0.2~
0.75)Us
(0.2~
0.75)Us
Coil power 50Hz

60Hz
 
 
Pick-up(VA) 70 70 110 110 110 200 200 200 200 200
Holding(VA) 8 8 11 11 11 20 20 20 20 20
Pick-up(VA) 80 80 115 115 115 200 200 200 200 200
Holding(VA) 8 8 11 11 11 20 20 20 20 20
Power
consumption
(W)
1.8~2.7 1.8~2.7 3~4 3~4 3~4 6~10 6~10 6~10 6~10 6~10

Auxiliary Contactor Vacuum Motor AC Contactor LC1-D
Auxiliary Contactor Vacuum Motor AC Contactor LC1-D


Auxiliary Contactor Vacuum Motor AC Contactor LC1-D

Company Introduction

Auxiliary Contactor Vacuum Motor AC Contactor LC1-D

Wenzhou Korlen Electric Appliances Co., Ltd, It is a joint venture. My company is a manufacturer including design, development, produce and sale, professional producing MCB, MCCB, RCCB and AC contactor etc. Product enterprises. The company owns import and export power of self-run, expanding Europe and America, Middle East, Southeast Asia etc. Market, set a good Public praise.

The company have more than 1500 workers, including senior engineer among them, engineer at inside of more than 100 technician. And then set up to cover area more than 50 acres, construct area is more than 38000 square meters of the modern industrial zone, providing with the forerunner's standard laboratory and various examination equipments.

Under Korlen people to make great effort unremittingly, designed and developed by oneself, develop and produce the series of MCB, RCCB filled up local blank, attain inter-national advanced level, and acquire more than 20 national patents. The company acquires "30 strong eminent enterprises, top ten of export income, yueqing star class enterprise, attach importance to contract and keeps promise" title of honor for many times past years. Company still the initiative pass ISO 9001 management system verification and 14001 environments management system verification. Our product passed quality verification of domestic and international authority organization like the CB\ SEMKO\ NF\ SIRIM\ SNI\ CE \PCT\ TSE, In the meantime high breaking capacity breaker of our company in this city is the unique product which got " Yueqing famous brand product" by Yueqing people government.

Korlen Electric Appliances is willing to make friends with social public, the world outside businessman join hands together for prosperous society and development to build a brighter future.



Certificates

Auxiliary Contactor Vacuum Motor AC Contactor LC1-D

Factory Lines

Auxiliary Contactor Vacuum Motor AC Contactor LC1-D
Auxiliary Contactor Vacuum Motor AC Contactor LC1-D

Exhibition

Auxiliary Contactor Vacuum Motor AC Contactor LC1-D


Auxiliary Contactor Vacuum Motor AC Contactor LC1-D


Auxiliary Contactor Vacuum Motor AC Contactor LC1-D
Auxiliary Contactor Vacuum Motor AC Contactor LC1-D



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier