ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: Conventional Circuit Breaker
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Other

Basic Info.

Model NO.
KNL6-63
Poles Number
4
Type
Circuit Breaker
Function
RCCB
Certification
VDE, CE, CB
Frame
63A
Rated Operation Current
16;20;25;32;40;50;63A
Rate Limiting Short Circuit Current
6000A
Rated Residual Operating Current
0.03;0.1;0.3;0.5A
Sensibility
AC; a; S Type
Standard
IEC/En 61008.1 and GB16916.1
Transport Package
Carton
Specification
IEC/EN61008.1 and GB 16916.1
Trademark
KORLEN
Origin
Wenzhou; Zhejiang; China
Production Capacity
500000PCS/Year

Product Description

KNL6 series Residual current circuit breaker(without over-current protection) is suitablefor the line of A and S 50/60Hz, voltage 230V(2pole)/400V(4pole), rated current up to 80A. Whenthere is human electricity shock or if the leakage current of the line exceeds the prescribedvalue, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation. It is applicable to industrial site, commercial site, tall building and civil house.

It complies with standard of IEC/EN61008.1 and GB16916.1.

Each phase of conductor at the circuit breaker passes through the zero-sequence

Current tr ansformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zerosequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn t zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.

Frame 63A
Rated working voltage 230/400V
Rated frequency 50/60Hz
Rated working current 16,25,40,63A
Rated residual operating current 0.03,0.1,0.3,0.5A
Rated residual un-operating current 0.015,0.05,0.15,0.25A
Sensibility A Type,AC Type,S Type
Maximum operating time IΔn t≤0.1s , 5IΔn t≤0.04
Rated making and breaking capacity In≤50A 500A,In=63A 630A,In=63A 1500A
Limiting value of un-operating current 6In
Rated limiting short-circuit current 10000A
Pole number 2,4P
Mechanical life 20000
Electric life 4000




ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63
ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63
ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63

Company Introduction

ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63

Wenzhou Korlen Electric Appliances Co., Ltd, It is a joint venture. My company is a manufacturer including design, development, produce and sale, professional producing MCB, MCCB, RCCB and AC contactor etc. Product enterprises. The company owns import and export power of self-run, expanding Europe and America, Middle East, Southeast Asia etc. Market, set a good Public praise.

The company have more than 1500 workers, including senior engineer among them, engineer at inside of more than 100 technician. And then set up to cover area more than 50 acres, construct area is more than 38000 square meters of the modern industrial zone, providing with the forerunner's standard laboratory and various examination equipments.

Under Korlen people to make great effort unremittingly, designed and developed by oneself, develop and produce the series of MCB, RCCB filled up local blank, attain inter-national advanced level, and acquire more than 20 national patents. The company acquires "30 strong eminent enterprises, top ten of export income, yueqing star class enterprise, attach importance to contract and keeps promise" title of honor for many times past years. Company still the initiative pass ISO 9001 management system verification and 14001 environments management system verification. Our product passed quality verification of domestic and international authority organization like the CB\ SEMKO\ NF\ SIRIM\ SNI\ CE \PCT\ TSE, In the meantime high breaking capacity breaker of our company in this city is the unique product which got " Yueqing famous brand product" by Yueqing people government.

Korlen Electric Appliances is willing to make friends with social public, the world outside businessman join hands together for prosperous society and development to build a brighter future.



Certificates

ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63

Factory Lines

ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63
ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63

Exhibition

ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63
ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63


ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63ELCB RCCB Residual Current Device Circuit Breaker RCD Knl6-63

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory, Other
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001