Residual Current Circuit Breaker (KNL1-100)

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Manufacturer/Factory, Other

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001
  • Residual Current Circuit Breaker (KNL1-100)
  • Residual Current Circuit Breaker (KNL1-100)
  • Residual Current Circuit Breaker (KNL1-100)
Find Similar Products

Basic Info.

Model NO.
KNL1-100
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
Conventional Circuit Breaker
Type
Circuit Breaker
Function
RCCB
Certification
CB
Transport Package
Carton
Specification
ROHS; CE; ISO
Trademark
KORLEN
Origin
Wenzhou; Zhejiang; China
Production Capacity
5000000PCS/Year

Product Description

KNL1 series Residual current circuit breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A.When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage.It can be used as infrequent changeover of the line in normal situation.It is applicable to industrial site, commercial site, tall building and civil house.
It complies with standard of IEC/EN61008.1 and GB16916.1.

Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper.Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero.The flux of the zero-sequence current transformer is zero.And the secondary output voltage is zero and the circuit breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage.Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.
Frame class 100A
Rated working voltage 240/415V
Rated frequency 50/60Hz
Rated working current 63,80,100A
Rated residual operating current 0.03,0.1,0.3,0.5A
Rated residual un-operating current 0.015,0.05,0.15,0.25A
Sensibility AC Type
Maximum operating time IΔn t≤0.1s , 5IΔn t≤0.04
Rated making and breaking capacity 1500A
Limiting value of un-operating current 6In
Rated limiting short-circuit current 3000A
Pole number 2,4P
Mechanical life 10000
Electric life 4000