Product Highlights

  • IEC and GB Compliance: Complies with IEC/EN61008.1 and GB16916.1 standards for safety and reliability.
  • Rapid Protection Response: Cuts off power within 0.1s to 0.3s to prevent electric shock and leakage accidents.
  • High Short-Circuit Capacity: Rated limiting short-circuit current up to 10000A for robust circuit protection.
  • Versatile Current Ratings: Available in rated working currents from 16A to 63A and residual currents 30mA to 500mA.
  • Long Mechanical Life: Endures 10,000 mechanical operations ensuring long-term durability.
  • Multi-Pole Configuration: Supports 2-pole and 4-pole configurations for 240V and 415V systems.
  • Wide Application Scope: Suitable for industrial, commercial, tall buildings, and residential civil housing.
  • Advanced Sensitivity Types: Offers A Type, AC Type, and S Type sensitivity for diverse leakage scenarios.

Product Images of Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1

Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1 pictures & photos
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1 pictures & photos
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1 pictures & photos
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1 pictures & photos
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1 pictures & photos
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1 pictures & photos
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
  • Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
  • Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
    Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
  • Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
    Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
  • Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
    Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
  • Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
    Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
  • Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
    Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
  • Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
    Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1

Find Similar Products

Product Description

KNL5-100 series Residual current circuit breaker(without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation. It is applicable to industrial site, commercial site, tall building and civil house.

It complies with standard of IEC/EN61008.1 and GB16916.1.

Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.
 
Frame class 63A
Rated working voltage 240/415V
Rated frequency 50/60Hz
Rated working current 16,20,25,32,40,50,63A
Rated residual operating current 0.1,0.3,0.5A
Rated residual un-operating current 0.05,0.15,0.25A
Sensibility A Type,AC Type,S Type
Maximum operating time IΔn t≤0.1s , 5IΔn t≤0.04
Rated making and breaking capacity In≤50A 500A,In=63A 630A , In>63A 1500A
Limiting value of un-operating current 6In
Rated limiting short-circuit current 10000A
Pole number 2,4P
Mechanical life 10000
Electric life 4000

Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1

Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1

Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1
Korlen Patented Residual Current Circuit Breaker RCCB Knl5-63 30, 100, 300, 500mA with IEC61008-1

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2531535". Items marked "verified" are certified.

Watch Video
Watch Video
GAONENGGELE ELECTRICAL SHARES CO.,LTD.
GAONENGGELE ELECTRICAL SHARES CO.,LTD.
GAONENGGELE ELECTRICAL SHARES CO.,LTD.
GAONENGGELE ELECTRICAL SHARES CO.,LTD.
GAONENGGELE ELECTRICAL SHARES CO.,LTD.
GAONENGGELE ELECTRICAL SHARES CO.,LTD.
GAONENGGELE ELECTRICAL SHARES CO.,LTD.
GAONENGGELE ELECTRICAL SHARES CO.,LTD.

About Our Factory & Business Background

Address
258 Wei 20 Road, Economic Development Zone, Yueqing City, Wenzhou City, Zhejiang Province

Our Production Capability & Technical Expertise

Main Products
Mini Circuit Breaker, RCBO, RCCB, MCCB, Contactor

Our Industry Experience & Global Business Record

Export Year
2015-03-11

FAQ

What is the rated working voltage?
The rated working voltage is 240V for 2-pole and 415V for 4-pole configurations.
What are the available rated working currents?
Rated working currents range from 16A, 20A, 25A, 32A, 40A, 50A to 63A.
What is the limiting short-circuit current?
The rated limiting short-circuit current is up to 10000A.
Does this product support different sensitivity types?
Yes, it supports A Type, AC Type, and S Type sensitivities.
What is the mechanical life of the circuit breaker?
The mechanical life is guaranteed for 10,000 operations.
Is this breaker suitable for industrial use?
Yes, it is applicable to industrial sites, commercial sites, tall buildings, and civil houses.
What standards does the product comply with?
It complies with IEC/EN61008.1 and GB16916.1 standards.