Can Carry 125A Miniature Circuit Breaker Knb1-125 MCB 10ka with Good Copper Silver Contact IEC60898/60947

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 1.8/Piece
Request Sample
Manufacturer/Factory, Other

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001
  • Can Carry 125A Miniature Circuit Breaker Knb1-125 MCB 10ka with Good Copper Silver Contact IEC60898/60947
  • Can Carry 125A Miniature Circuit Breaker Knb1-125 MCB 10ka with Good Copper Silver Contact IEC60898/60947
  • Can Carry 125A Miniature Circuit Breaker Knb1-125 MCB 10ka with Good Copper Silver Contact IEC60898/60947
  • Can Carry 125A Miniature Circuit Breaker Knb1-125 MCB 10ka with Good Copper Silver Contact IEC60898/60947
Find Similar Products

Basic Info.

Model NO.
KNB1-125
Arc-extinguishing Medium
Air
Structure
MCB
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC
Release Type
B C D
ISO
ISO9001 ISO14001
Rated Working Voltage
240V/415V
Making and Breaking Capacity
10ka
Mechanical Life
20000
Electric Life
4000
Rated Frequency
50/60Hz
Pole
1,2,3,4
Rated Working Current
63A,80A,100A,125A
Transport Package
Carton
Specification
1P 7.78x7.85x17.8mm
Trademark
KORLEN
Origin
China
HS Code
8536200000
Production Capacity
2000000/Month

Product Description

  Standard
 
  IEC/EN 60898-1
 
IEC/EN 60947-2
 
Electrical features Rated current In
 
A         1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50,63
 
Poles
 
  1P, 1P+N, 2P, 3P, 3P+N, 4P
 
1P, 2P, 3P, 4P
 
Rated voltage Ue
 
V                                 230/400~240/415
Insulation voltage Ui
 
V 500
Rated frequency
 
  50/60Hz
Rated breaking capacity
 
A 10000 10000
Energy limiting class
 
  3  
Rated impulse withstand voltage(1.2/50) Uimp
 
V 4000
Dielectric test voltage at ind. Freq. for 1 min
 
KV 2 1.890
Pollution degree
 
  2
Power loss per pole   Rated current (A) 
 
Max power loss per pole (W)
 
  1, 2, 3, 4, 6, 10
 
2
  16, 20, 25, 32
 
3.5
  40, 50, 63
 
5
Thermo-magnetic release characteristic
 
  B, C, D
 
(8-12)In
 
Mechanical features Electrical life
 
  4000
Mechanical lif
 
  20000
Contact position indicator
 
  YES
Protection degree
 
  IP20
Reference temperature for setting of thermal element

 
ºC
 
30
Ambient temperature (with
daily average≤35ºC)
 
ºC
 
-5...+40
Storage temperation
 
ºC
 
-25...+70
Installation Terminal connection type
 
  Cable/U-type busbar/Pin-type busbar
Terminal size top/bottom for  cable mm2
 
25
AWG
 
18-4
Terminal size top/bottom for  busbar mm2
 
10
AWG 18-8
Tightening torque N·m 2.5
In-Ibs. 22
Mounting   On DIN rail EN 60715 (35mm) by means of fast clip device
Connection   From top and bottom
Combination with accessories Auxiliary contact   YES
Shunt release   YES
Under voltage release   YES
Alarm contant   YES
 
    1. Selectivity
 







Load side: K    NB1-63, KNB1-63H
Curve B, C
In (A) Power supply side: RT36-00 (fuse)
20 25 36 50 63 80 100 125 160
Is (kA)
≤2 1.2 4 >12 >12 >12 >12 >12 >12 >12
3 0.7 1.2 3.8 5.3 6 6 6 6 6
4 0.6 0.9 2.5 3.8 6 6 6 6 6
6 0.5 0.8 1.9 2.5 4.5 5 6 6 6
10   0.7 1.4 2.2 3.2 3.6 6 6 6
16     1.2 1.8 2.6 3 5.6 6 6
20       1.5 2.2 2.5 4.6 6 6
25       1.3 2 2.2 4.1 5.5 6
32         1.7 1.9 3.8 4.5 6
40           1.7 3 4 5
50           1.5 2.6 3.5 4.5
63             2.4 3.3 4.5
 




Load side: KNB1-63, KNB1-63H
Curve B, C
In (A) Power supply side: NM8-100S/H/R
16 20 25 32 40 50 63 80 100
Is (kA)
≤10 0.19 0.19 0.3 0.4 0.5 0.5 0.5 0.63 0.8
16     0.3 0.4 0.5 0.5 0.5 0.63 0.8
20         0.5 0.5 0.5 0.63 0.8
25           0.5 0.5 0.63 0.8
32             0.5 0.63 0.8
40               0.63 0.8
50                 0.8
63                  
    1. Backup protection
 






Load side:K NB1-63, KNB1-63H
Curve B, C
In (A) Power supply side: RT16 series
40 50 63 80 100 125 160
Is (kA)
1~6 40 40 40 40 40 40 40
8~10 40 40 40 40 40 40 40
13 40 40 40 40 35 35 35
16 40 40 40 40 30 30 30
20 40 40 40 40 30 30 30
25 40 40 40 40 30 30 30
32 40 40 40 40 30 30 30
40 40 40 40 40 30 30 30
50 30 30 30 30 30 30 30
63 20 20 20 20 15 15 15
 


Load side: KNB1-63, KNB1-63H
Curve B, C
In (A) Power supply side: NM8
NM8-125S NM8-125H NM8-125R NM8-250S NM8-250H NM8-250R
Is (kA)
1~6 15 18 18 15 15 15
10~20 12 15 15 12 12 12
32~40 12 15 15 12 12 12
50~60 12 15 15 12 12 12
Can Carry 125A Miniature Circuit Breaker Knb1-125 MCB 10ka with Good Copper Silver Contact IEC60898/60947


 
    1. Temperature derating
The maximum permissible current in a circuit breaker depends on the ambient temperature where the circuit breaker is
placed. Ambient temperature is the temperature inside the enclosure or switchboard in which the circuit breakers are installed.

The reference temperature is 30ºC

 
Ambient temperature                        
  -35ºC -30ºC -20ºC -10ºC 0ºC 10ºC 20ºC 30ºC 40ºC 50ºC 60ºC 70ºC
Rated current(A)                        
1 1.30 1.26 1.23 1.19 1.15 1.11 1.05 1.00 0.96 0.93 0.88 0.83
2 2.60 2.52 2.46 2.38 2.28 2.20 2.08 2.00 1.92 1.86 1.76 1.66
3 3.90 3.78 3.69 3.57 3.42 3.30 3.12 3.00 2.88 2.79 2.64 2.49
4 5.20 5.04 4.92 4.76 4.56 4.40 4.16 4.00 3.84 3.76 3.52 3.32
6 7.80 7.56 7.38 7.14 6.84 6.60 6.24 6.00 5.76 5.64 5.28 4.98
10 13.20 12.70 12.50 12.00 11.50 11.10 10.60 10.00 9.60 9.30 8.90 8.40
16 21.12 20.48 20.00 19.20 18.40 17.76 16.96 16.00 15.36 14.88 14.24 13.44
20 26.40 25.60 25.00 24.00 23.00 22.20 21.20 20.00 19.20 18.60 17.80 16.8
25 33.00 32.00 31.25 30.00 28.75 27.75 26.50 25.00 24.00 23.25 22.25 21.00
32 42.56 41.28 40.00 38.72 37.12 35.52 33.92 32.00 30.72 29.76 28.16 26.88
40 53.20 51.20 50.00 48.00 46.40 44.80 42.40 40.00 38.40 37.20 35.60 33.6
50 67.00 65.50 63.00 60.50 58.00 56.00 53.00 50.00 48.00 46.50 44.00 41.50
63 83.79 81.90 80.01 76.86 73.71 70.56 66.78 63.00 60.48 58.90 55.44 52.29


When several simultaneously operating circuit breakers are mounted side by side in a small enclosure, the temperature rise inside the enclosure causes a reduction in current rating.
You must then assign the rating (already derated if necessary according to ambient temperatuer) a downrating factor of 0.8.


Can Carry 125A Miniature Circuit Breaker Knb1-125 MCB 10ka with Good Copper Silver Contact IEC60898/60947
Can Carry 125A Miniature Circuit Breaker Knb1-125 MCB 10ka with Good Copper Silver Contact IEC60898/60947
Can Carry 125A Miniature Circuit Breaker Knb1-125 MCB 10ka with Good Copper Silver Contact IEC60898/60947

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier